Conductive (Direct Connect) Mode
Whenever possible, the conductive method is preferred for energizing the con-
ductor. By using a direct hookup, the operator can help eliminate locating mis-

and air coupling.

By using a direct energizing method, the operator helps isolate the target connec-

grounding cables, grounding plate, grounding spike, and bridging cable.

WaRNING!

SaFeTY FIRST!

Check for and turn off all power source(s) before connecting the trans-

mitter directly to power carrying cables.

Direct connection must NOT be to live 50/60 hertz power sources up to

240 VaC. The power must be OFF!!

Be certain the transmitter POWeR is off before handling the clips on

the conductive assembly. The Sure-Lock transmitter can deliver 100

volts of signal which is capable of producing electrical shock if not

carefully handled.

The ReD cable should then be connected to the conductor to be traced. A good
connection to the conductors is essential for a clear, strong signal. Any rust,
corrosion, or paint should be removed in order to obtain a good metal to metal
contact.

The BLaCK

obtain a good ground. a GOOD GROUND IS eSSeNTIaL! It is generally
advisable to ground perpendicular to the structure being traced. The operator

as a ground. The cables are carrying the full signal current, and, if the operator