HITEC X1-200 Touch: DC/DC, Multi-Chemistry, Touch Screen Battery Charger User Manual

Page 10

Advertising
background image

18

19

CHARGER OPERATIONS (cont.)

2. CHARGING PROGRAM
The available program modes are dependent on the battery type used. The
chart below lists the different operations available for each type of battery.
Use the up

▲ and down ▼ arrows on the screen to find the program opera-

tion you wish to use.

BATTERY

TYPE

PROGRAM

OPERATION

DESCRIPTION

LiPo

LiIon

LiFe

CHARGE

This is the normal CHARGING mode for Lithium chemistry batteries.

DISCHARGE

This is the normal DISCHARGING mode for Lithium chemistry batteries.

STORAGE

Storage Mode is best used for charging or discharging Lithium chemistry
batteries that will be stored for a long period of time.

FAST CHG.

With Fast Mode Charging, the total charge capacity is reduced but the
charge process will take less time.

BAL. CHARGE

Balance Charging balances the voltage of each cell while charging.

Note: WE HIGHLY RECOMMEND CHARGING LITHIUM BATTERIES IN

BALANCE MODE.

VOLT METER

Volt Meter is used to check the Lithium chemistry battery’s total voltage,
the highest and lowest voltage and each cell’s individual voltage.

NiCd

NiMH

CHARGE

This is the normal CHARGING mode for NiCd and NiMH batteries using
the current set by the user.

AUTO CHG.

In Auto Charge Mode, the charger automatically detects the connected
NiMH or NiCd battery and determines the proper full charge and cutoff
thresholds.

NOTE: Setting the upper charge current limit for safe levels based on

your battery specifications will ensure safe charging of your specific

battery.

DISCHARGE

This is the Normal Mode for discharging NiMH/NiCd batteries.

RE-PEAK

In Re-peak Mode, the charger will automatically peak charge the battery
once, twice or three times in a row. This process is good for confirming
the battery is fully charged and for verifying how well the battery can
accept a fast charge.

CYCLE

In Cycle Mode, you can program the charger to automatically process
up to 5 charge/discharge or discharge/charge cycles. This is helpful for
refreshing and balancing the battery’s performance.

VOLT METER

The user can check NiCd or NiMH battery pack’s total voltage.

Pb

Lead

Acid

CHARGE

Standard Charge Mode for Pb type batteries.

DISCHARGE

Standard Discharge Mode for Pb type batteries.

VOLT METER

The user can check Pb (Lead Acid) battery pack’s total voltage.

CHARGER OPERATIONS (cont.)

3. PROGRAM START
Touch the start button or touch and hold the framed Operation Program
for 3 seconds to start the program. The charger will check the number of
battery cells automatically. If the detected result and your setting match, the
charger will begin the selected operation.

Information Displayed during Operation

If the settings are incorrect, an error message will be displayed. Touch the Home
button to go back to the main menu and correct the setting before proceeding.

Battery Information >

< Current Operations

Elapsed Time >

< External Temperature*

Charge/Discharge >

< Internal Temperature

Capacity Supplied >

< Pack Voltage

Current

*when used with optional

temperature probe

Advertising