HITEC X1-200 Touch: DC/DC, Multi-Chemistry, Touch Screen Battery Charger User Manual

Page 12

Advertising
background image

22

23

CHARGER OPERATIONS (cont.)

Connecting a Lithium chemistry
battery attached to a balance board
to see individual cell voltages.

Connecting a battery directly to the
charger to see the total voltage of
a pack.

USING THE CHARGE MASTER CHARGE CONTROL SOFTWARE
Visit the Hitec RCD USA (www.hitecrcd.com) website to download the free
CHARGE MASTER software for Windows PC’s. With the Charge Master soft-
ware, you can control your charger settings, initiate the operation process,
monitor a variety of processes, load data and update your charger’s fi rm-
ware.

VOLT METER
Using the VOLT METER function, you have the ability to check the total volt-
age of your battery pack. If you are checking a Lithium chemistry battery
attached to a balancing board, you can also see the highest voltage, lowest
voltage and each individual cell’s voltage.

MEMORY PRESETS – DATA STORE/LOAD

The X1-200 Touch charger can store up to 5 diff erent charge/discharge

profi les for your convenience. These stored profi les can be recalled quickly

without having to go through the setup process.

1. STORING PRESETS

Enter the Presets menu and touch edit next to the preset you would like to

create. Select the Battery Type, Number of Cells, Operation, Charge Current

and Discharge Current, then touch CONFIRM to save the data and return to

the previous screen.

2. RECALLING DATA

In the PRESET menu, the basic settings of the profi les are displayed. To use

a preset, touch the desired preset settings bar to select it. You will then be

returned to the Main Menu and the setting of the selected preset will be

displayed at the top of the screen. Press start to execute the operation.

ERROR MESSAGES

The X1-200 Touch incorporates a variety of functions to verify the operation

and the state of the electronics. In the event of an error, the error screen will

display the cause of the error and emit an audible sound.

CHARGER OPERATIONS (cont.)

INT. TEMP TOO HIGH

The internal temperature of the unit is too high, terminate the process and

allow the unit to cool down.

EXT. TEMP TOO HIGH

The temperature detected by the external temperature probe has exceeded

the limit set by the user.

DC IN TOO LOW

Input voltage is less than 11V.

DC IN TOO HIGH

Input voltage is higher than 18V.

OVER TIME LIMIT

The charging time has exceeded the maximum charging time set by the user.

OVER CAPACITY LIMIT

The battery capacity has exceeded the maximum capacity set by the user.

REVERSE POLARITY

Incorrect polarity detected.

CONNECTION BREAK

The battery connection has been lost or interrupted.

CELL NUMBER ERROR

The cell number entered during setup is incorrect.

BALANCE CONNECTER

ERROR

The balance connection is wrong. Check the connections and try again.

NO BATTERY

There is no battery connected to the charger.

CONNECTION ERROR

There is an error in the battery connection, check connection and try again.

BATTERY WAS FULL

When Charging in balance mode, the charger has detected that the cell

voltages have exceeded the user’s specifi ed voltage.

Advertising