Specifications, 1 optical and electrical, 2 dimensions and weight – Kipp&Zonen CMA 6 Albedometers User Manual

Page 29: 1 optical and electrical 6.2 dimensions and weight

Advertising
background image

29

Instruction Manual - CMP/CMA series

.

Kipp & Zonen reserves the right to make changes to specifications and other product documentation without prior notice.

6.1 Optical and electrical

6.2 Dimensions and weight

CMP 3

CMP 6, CMP10, CMP 11, CMP 21 and CMP 22

CMA 6 and CMA 11

Weight without cable: 0.3 kg

Weight without cable: 0.6 kg

Weight without cable: 1.2 kg

6. Specifications

68 mm

Ø32 mm

Ø110 mm

Ø128 mm

Ø50 mm

Ø150 mm

464 mm

114 mm

Ø16 mm

68 mm

Ø50 mm

Ø150 mm

Ø150 mm

Specifications

CMP 3

CMP 22

CMP 21

CMP 6

Classification to ISO 9060:1990
Spectral range

(50% points)

Sensitivity
Impedance
Expected output range

(0 to 1500 W/m²)

Maximum operational irradiance

2000 W/m²

Response time

(63%)

Response time

(95%)

Zero offsets

(a)

thermal radiation

(at 200 W/m²)

(b)

temperature change

(5 K/h)

Non-stability

(change/year)

Second Class
300 to 2800nm
5 to 20µV/W/m²
20 to 200Ω
0 to 30mV

< 6s

< 18s

< 15 W/m²

< 5 W/m²
< 1%

Non-linearity

(100 to 1000 W/m²)

< 1.5%

Directional response

(up to 80° with 1000 W/m² beam)

< 20 W/m²

Spectral selectivity

(350 to 1500 nm)

< 3%

Temperature response

< 5%

(-10°C to +40°C)

Field of view

180°

Temperature sensor output

Operational temperature range

-40°C to +80°C

Humidity range

0 to 100% non-condensing

Tilt response

(0° to 90° at 1000 W/m²)

< 1%

Accuracy of bubble level

< 0.2°

Detector type

Thermopile

Storage temperature range

-40°C to +80°C

Ingress Protection (IP) rating
Recommended applications

67
Economical solution for

routine measurements in

weather stations,

field testing

4000 W/m²

Secondary Standard
285 to 2800nm
7 to 14µV/W/m²
10 to 100Ω
0 to 20mV

< 1.7s

< 5s

< 7 W/m²

< 2 W/m²
< 0.5%
< 0.2%
< 10 W/m²

< 3%
< 1%

(-20°C to +50°C)

180°

-40°C to +80°C

0 to 100% non-condensing

< 0.2%

< 0.1°
10K Thermistor

(optional Pt-100)

Thermopile

-40°C to +80°C

67

4000 W/m²

Secondary Standard
200 to 3600nm
7 to 14µV/W/m²
10 to 100Ω
0 to 20mV

< 1.7s

< 5s

< 3W/m²

< 1W/m²
< 0.5%
< 0.2%
< 5 W/m²

< 3%
< 0.5%

(-20°C to +50°C)

180°

-40°C to +80°C

0 to 100% non-condensing

< 0.2%

< 0.1°
10K Thermistor

(optional Pt-100)

Thermopile

-40°C to +80°C

67

2000 W/m²

First Class
285 to 2800nm
5 to 20µV/W/m²
20 to 200Ω
0 to 30mV

< 6s

< 18s

< 12 W/m²

< 4 W/m²
< 1%
< 1%
< 20 W/m²

< 3%
< 4%

(-10°C to +40°C)

180°

-40°C to +80°C

0 to 100% non-condensing

< 1%

< 0.1°

Thermopile

-40°C to +80°C

67
Good quality measurements

for hydrology networks,

greenhouse climate control

Note: The performance specifications quoted are worst-case and/or maximum values

Standard 10k Thermistor or optional Pt-100 temperature sensor with CMP 21 and CMP 22

Individual directional response and temperature dependence test data with CMP 21 and CMP 22

4000 W/m²

Secondary Standard
285 to 2800nm
7 to 14µV/W/m²
10 to 100Ω
0 to 20mV

< 1.7s

< 5s

< 7 W/m²

< 2 W/m²
< 0.5%
< 0.2%
< 10 W/m²

< 3%
< 1%

(-10°C to +40°C)

180°

-40°C to +80°C

0 to 100% non-condensing

< 0.2%

< 0.1°

Thermopile

-40°C to +80°C

67

Meteorological networks,

reference measurements in

extreme climates, polar

or arid

Scientific research

requiring the highest level

of measurement accuracy

and reliability

Meteorological networks,

PV panel and thermal

collector testing,

materials testing

CMP10 & CMP 11