Konig Electronic Gas detector User Manual

Page 2

Advertising
background image

ENGLISH

2

Introduction

Guarantee your own safety in the house with this useful free standing

flammable gas alarm, household type made for indoor use only. When the gas

concentration reaches a certain level the detector provides a visual and audible

signal.

Warning

The service life of the gas detector is for 3 years guaranteed. For optimal

protection we recommend replacing the gas detector every 3 years.

Specifications

• Detectable gases: Natural gas: methane, ethane, propane, and butane.

Liquefied petroleum gas (LPG): propane, butane, propylene and butylene

• Power: 100-240 V AC~ 50/60 Hz

• Rated load: < 2 W

• Alarm level: 3% LEL~20% LEL

• Alarm volume: > 85 dB

• Temperature range: -10°C ~ 50°C

• Relative humidity: < 97% RH

• Storage temperature: -10°C~+40°C

• Dimensions: 67 x 67 x 112 mm

• Weight: 122 g

Where to install the gas detector

Before installing the gas detector we recommend checking, which type of gas

is relevant for the room(s) you are placing a gas detector in.

Natural gas and town gas

It should be installed in the room(s) where a gas leak is most likely to occur;

installed above the level of a possible gas leak and near the ceiling; typically

0.3 m from the ceiling, in a place where air movement is not impeded by

furniture and furnishings.

LPG

It should be installed in the room(s) where the most frequently used appliance

is accommodated and where a leak is most likely to occur. Install as low as

possible; typically 0.1 m above the floor and in a place where air movement is

not impeded by furniture.