Where not to install the gas detector

• In a small enclosed space

• Directly above a sink

• Next to a door or window

• Next to an extractor fan

• In an area where the temperature may drop below -10°C or exceed 40°C

• Where dirt and dust may block the sensor

• In a damp or humid location

Operation

Display gas level

indicator

Gas sensor

Alarm buzzer

Alarm indicator

State indicator

Power indicator

1. Connect the gas detector to a power outlet. The green power indicator is

constantly on, and it alarms with beep sound (red alarm indicator flashes

twice). The display gas level indicator displays “-” for about 4 minutes. Then

the gas detector starts the alarm detection mode.

2. When the concentration is 0, 1 or 2 the status indicator is off.

3. When the concentration is 3, the status indicator is red and the alarm

indicator flashes. When the concentration is 3, 4 or 5, it alarms with a slow

beep tone.

4. When the concentration is 6, 7, 8 or 9 it alarms with a fast beep tone.

5. When the display gas level indicator concentration is A, it alarms with the

status indicator in red, alarm indicator constantly on in red.