Purifier logic+ accessories, Ventus, Canopy connection kit – Labconco PURICARE Procedure Station Models 31260 User Manual

Page 135

Advertising
background image

Product Service 1-800-522-7658

135

Section Eight –

Purifier Logic+ Accessories

Ventus

TM

Canopy Connection Kit

P/N 3889200, -01, -02, -03

Section 1. – Theory of Operation

The Ventus canopy system consists of a high efficiency, low profile canopy that

interfaces directly with the Logic+’s control board. Ventus offers several features that

are a distinct improvement over prior canopy designs:

The alarm system is simple, rugged, and durable; a magnetic reed switch

located on the intake valve.

The intake valve is angled such that the incoming make-up (room) air

must keep the valve open to maintain normal operation; a loss of exhaust

volume will allow gravity to close the inlet valve and open the magnetic

switch, resulting in a canopy alarm.

During a canopy alarm, in addition to the audible and visual alarms, relief

valves in the canopy will open, and the control board will run the Logic+’s

blower at full speed. These coordinated actions will help to maintain a

safe inflow to protect the operator during the alarm.

Optional Damper

Intake Valve

Alarm Switch


Relief Valve





NOTE: If the canopy was installed at the factory, go directly to Page 5, Section 4.

NOTE: Before beginning this installation, Turn the unit on, press the Menu button, select the

Services option, then the Current Settings. This will bring up the current settings screen.

Record the motor’s ECM Setting and the motor’s average RPMs once the unit operation

stabilizes.

NOTE: Exercise caution when removing or installing the exhaust filter cover, to prevent

damaging the Exhaust HEPA filter.