3. OPERATING GUIDE

ALPHA C-25 Manual V2.1.doc

Page 10

It is recommended that a visual inspection of the battery is carried out in
conjunction with testing and charging batteries. The charging, unless otherwise
specified in the manufacturer's CMM/

ICA, shall be conducted at room ambient

temperature of 70°F to 85°F (21°C to 29°C).

3.3.1 VERIFY THE CP VOLTAGE

The CP

voltage (in all modes) can be verified by the following steps: 1) turn unit

power off; 2) disconnect all batteries; 3) turn charge current to max; 4) turn unit
power on; and 5) verify

the CP voltage on the Alpha C-25 digital voltmeter (see

also section 4.5 on modifying the operating range).

WARNING: Always turn the AC power switch off before
connecting or disconnecting a battery

NOTE: Once set, all settings are maintained and need not
be reset for duplicate charging

A. SWITCH OFF MAINS POWER

Turn off the AC on-off/reset power switch.

B. TURN DOWN CHARGE CURRENT

Repeatedly turn the Ampere Adjust knob fully
counter-clockwise to set charge current to
zero.