5. TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

A. Unit will not

turn on

The AC power is not
connected to unit

Check AC line with voltmeter

AC line fuse is blown. May be
due to incorrect AC line
voltage setting.

Ensure correct AC line voltage
setting on back of unit. (see section
2.1)

Replace AC line fuse located on the
lower right hand side on the rear of
the unit (see section 4.6)

B. Unit turns on

but will not start
(timing)

Timer is set to zero time,

Increase the timer setting (see
section 3.4)

C. No or very low

charge current

The lead-acid battery is
sulfated and will not support a
load

Recondition or discard the battery

High resistance or open
circuit in DC cable at quick
disconnect, in the cable itself

Inspect and measure resistance in
DC cable and connector. If high or
intermittent high resistance, the
cable needs to be replaced

The lead-acid battery is
sulfated.

Recondition the battery.

The nickel-cadmium battery
inter-cell connectors are loose
or contaminated causing high
resistance

Check all terminals and inter-cell
connectors. Set a low discharge
current and look for arcing or heat
generation.

D. Timer setting

cannot be
changed

Timer setting is locked.

Push timer’s “Lock” button.