Versa drawer™ alarm, Versa drawer™ refrigeration units – Delfield Versa Drawer User Manual

Page 14

Advertising
background image

1

Versa Drawer™ Refrigeration Units

Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (800) 733-8829 · Fax (989) 773-3210

Versa Drawer™ Alarm

Alarm Information

Alarm

Meaning

Action

Alternate Action

Thaw Finished

Thaw cycle is complete and unit

Press corresponding drawer

is now in refrigeration mode.

number to clear audio and screen.

Chiller Finished

Chiller cycle has completed and unit Press corresponding drawer

is now in refrigeration mode.

number to clear audio and screen.

Drawer Open

Drawer's been open for greater

Close drawer.

than set time.

Drawer temperature

Drawer temperature's been

Press corresponding drawer

Out of Range.

10 deg F above or below setpoint

number to clear audio and screen.

for more than 15 minutes.

Loss of power

Power to unit was interrupted.

Press i button to stop audio alarm.

Screen will change to display time

power failed, time power was restored.

Present time. Press i button once

more to return to main screen

Drawer temperature

Temperature probe to drawer box

Press i button to stop audio alarm,

probe(s) out of range.

or evaporator is damage or

screen will clear once temperature drops

temperature is out of range.

into range or probe is repaired.

Condenser temperature

Temperature probe to condenser

Press i button to stop audio alarm,

probe(s) out of range.

is damage or temperature is

screen will clear once temperature drops

out of range.

into range or probe is repaired.

Compressor pressure

Pressure transducer damaged

Press i button to stop audio alarm.

transducer(s) out of

or pressure is higher than 150 psi

If unit is started in high ambient alarm will

range.

clear on pulldown. If diagnostics shows

"open" for transducer, component must

be repaired.

Condenser fan(s) failure Condenser fan has fail to pull down Press i button to stop

The screen will clear if power to the unit

condenser outlet by 1 degree over

audio alarm. Alarm will remain on

is disconnected and reconnected. If

two minutes. Condenser fan may

screen until service work is performed

alarm keeps reoccurring after power

not be operating or condenser

has been removed service is required.

coil is dirty.

Compressor(s)

Compressor has failed to decrease Press i button to stop

The screen will clear if power to the unit

Failure

suction pressure.

audio alarm. Alarm will remain on

is disconnected and reconnected. If

screen until service work is performed

alarm keeps reoccurring after power

has been removed service is required.