Lodar 4 Function AC relay Receiver, Master and IP Series Transmitter User Manual

Page 4

Advertising
background image

Connection Detail - Switch V

oltage and Supply V

oltage are different,

Say mains supply and switching 48 V

olts

AC from a transformer

*If a switch is not used, its input must still be wired, otherwise if its corresponding

T

ransmitter Function is operated in error the Receiver will immediately switch of

f.

NOTE

Operating when the switched

V

oltage is at low as 48 V

olts,

the LED’

s will be very dim!

F1

Safety

F1

Switch

F2

Safety

F2

Switch

F3

Safety

F3

Switch

F4

Safety

F4

Switch

M

Safety

M

Switch

Power Supply

90 - 264 V

AC

for control circuits

ST -

LK1

LK2

RS232

ANT

Radio Module

Internal Aerial

glue

W

ire is not supplied with Lodar 96 and 97 Series systems, local wiring regulations apply

48 V

olts

AC

from

transformer

Secondary

Common Live

Output 1

Output 2

Output 3

Master Output

Primary

power

supply

Earth

Live (Hot)

Neutral

Secondary

Neutral

48 V

olts

AC

from

transformer

required for

safety circuit

Common Live Loop

Important

ALL

inputs must

be wired

*

see note below