Section 8 – Miscellaneous Commands

Radiance 2022 and Radiance 2042

rev 082813

28

On/Off Message

A programmable string can be sent to another device via the RS-232 connector to turn the device on or off.

The command is:

MENU Other OnOff Setup (On Message, Off Message)

Message Control

This sets the RS-232 parameters that are used for sending a power on/off message to another device. The

command is:

MENU Other OnOff Setup Message Ctl

Test Patterns

Warning:

Test patterns can burn plasma and CRT displays if left on for more then a few seconds.

The user can select from a large selection of test patterns. While in the test pattern menu the  and 

arrows select a test pattern group. Press the “4” button to step though the test patterns in a group. For

many test patterns the intensity can be adjusted from 0 to 100 IRE, in 5 IRE steps, using the  and 

arrows. Reference test patterns are only affected by the output PC/Video level setting. Adjustable patterns

allow viewing the effect of the output color management settings. The Warm Up test pattern displays a 20

IRE to 50 IRE gray screen.
To exit the test pattern command but leave the pattern on-screen, press “OK”. You can then adjust various

parameters to judge their effect on the pattern. Press “Prev” to then toggle between the source and the

pattern. Press “Alt” to jump back into the pattern command. The “Prev” and “Alt” functions are only valid

if leave the pattern on-screen by pressing “Ok”. The ten video inputs are numbered 1 to 10. For inputs 1

through 9, press the “Input” button and then press the corresponding number button on the remote. For

input 10, press the “Input” button, then the “0” button”. The command is:

MENU Other Test Pattern Pattern (Reference, Adjustable, Warm up)

Remote Control

Allows changing the default command usage of the arrow buttons on the remote. By default the Up/Down

arrow buttons can be used to control zoom. The Right/Left arrow buttons can be used to select the input

aspect ratio. You can turn off these additional functions by selecting “Off”. The command is:

MENUOtherI/O SetupRemote Ctl(Up/Down arrows, Rt/Left arrows)(On, Off)

LED Setup

This command controls the operation of the Green LED on the front panel. The LED can be set to “Green” to

be a power on indicator or set to “Dark” so that it is off when the Radiance is operating. The command is:

MENU Other I/O Setup LED Setup (Green, Dark)

RS-232 Setup

With echo on the Radiance will echo all characters sent to it. With echo off the Radiance will only send a

message at power on/off. With echo set to off with status, the power on/off messages are changed to

status responses. See Tech Tip 11 for delimiter usage and more details. The command is:

MENU Other I/O Setup RS-232 Setup (Echo, Delimiters) (On, Off)

3D Glasses

NOTE: Generally the display controls the 3D glasses. In this case the 3D Glasses command is not used.

These settings control the Lumagen CRT-3D Eyeglass Adapter when it is connected the HDMI output on the

Radiance. The delay setting adjusts when the shutter-glasses switch eyes. If the 3D effect doesn’t look

correct it may be that the left and right eyes are swapped. Changing the polarity would then correct this.

The command is:

MENU Other I/O Setup 3D Glasses (Delay, Polarity, Enable)