Test keypad, Control board connections, Status program calling granted – Mighty Mule FM136 User Manual

Page 4

Advertising
background image

2

rev - 09-20-10

ON

ALARM

ACCESSORY

RCVR

SEQ1

SEQ2

LEARN

BLU

ORG

WHT

GRN

R B G

Connect

#1 wire from the

RELAY OUTPUT terminals

on the keypad to

WHT

terminal on the gate opener

control board.

Connect

#2 wire

from the

RELAY OUTPUT

terminals on the keypad to the

GRN terminal on the gate

opener control board.

PRO-1000/2000, PRO-SL1000/SL2000 and Old Mighty Mule

Control Boards

#1

#2

RELAY

OUTPUT

AC/DC

POWER IN

1 2 3 4 5 6 7 8 9

+

0

Jumper ON

wireless mode

Jumper OFF

Hard-wire from Gate Opener

Power Supply from

Opener Battery

#

1

#

2

wired mode

Step 2:

Strip 3/16" off the ends of one pair of low voltage wires. Attach the wires to the terminal

block marked RELAY OUTPUT on the keypad control board as shown. Connect the other

end of the wires to the gate opener’s control board as shown in Control Board Connections

(below).
Step 3:

Strip 3/16" off the ends of the second pair of low voltage wires.

Attach the wires to the terminal block marked AC/DC POWER IN

on the keypad control board as shown. Connect the other end of

the wires to the opener’s battery: one end to the POSITIVE

(RED) pole and the other to the NEGATIVE (BLACK) pole.
Step 4:

Connect the jumper between the two terminals on the

keypad control board (ON) as shown.
Step 5:

Slide the keypad into the

housing and secure with the small

screws provided.
Step 6:

Replace the control board cover

and turn the power switch ON.

1

2

ABC

3

DEF

4

GHI

5

JKL

6

MNO

7

PRS

8

TUV

9

WXY

0

CALL

STATUS

PROGRAM

CALLING

GRANTED

Control Board Connections

If your control board doesn’t look like any of these diagrams, please refer to your gate opener

installation manual or call GTO Technical Service at 1-800-543-1236 or 850-575-4144.

GRN

B�K

R�D

RECEIVER

��M ��M

�����

�����

��

���

��

���

�AF�T�

�XIT

�P�N

�HAD�W

���P

��

���

�DG�

�P�N

�DG�

���

���

�8

��2

GTO/PRO DC Powered PRO-SW3000

and PRO-SW4000 Control Boards

Connect

#1 wire from the

RELAY OUTPUT terminals on

the keypad to

CYCLE terminal on

the gate opener control board.

Connect

#2 wire from

the

RELAY OUTPUT

terminals on the keypad

to the

COM terminal on

the gate opener control

board.

#1

#2

RECR

GRN

BLK

RED

EXIT

SAFETY

EDGE

CY

CLE

COMMON

LINK

Mighty Mule 350 Control Board

Connect

#1 wire from the

RELAY OUTPUT terminals

on the keypad to

CYCLE

terminal on the gate opener

control board.

Connect

#2 wire from the RELAY

OUTPUT terminals on the keypad

to the

COMMMON terminal on

the gate opener control board.

#1

#2

RECEIVER

COM COM

CY

CLE

CL

OSE

SAFETY

EXIT/ OPEN

SHADOW LOOP

CL

OSE

EDGE

OPEN EDGE

BLK

GRN

RED

Mighty Mule 500 & 502

Control Boards

Connect the

#1 wire from

RELAY OUTPUT terminals on the

keypad

to the

CYCLE terminal on

the opener control board.

Connect the

#2 wire from

the

RELAY OUTPUT

terminals on the keypad

to

one of the

COMMON

terminals on the opener

control board.

#1

#2

RECEIVER

ALM

GTO RCVR.

CO

M

GRN

BLK

RED

CY

CLE

SAFET

Y

EXIT

SHADO

W

OPEN EDGE

CO

M

CONTROL INPUTS

CL

OSE

EDGE

Connect

#1 wire from

the

RELAY OUTPUT terminals

on the keypad to

CYCLE terminal

on the gate opener control board.

Connect

#2 wire from the

RELAY OUTPUT terminals

on the keypad to the

COM

terminal on the gate opener

control board.

#1

#2

GEN-3 (Blue) Control Boards

COM

COM

COM

G

TO Inc.

SX4000 L

CY

CLE

SAFETY

OPEN EDGE

RUN 2

OPEN

CL

OSE

STOP

COM

COM

COM

SHADOW

LOOP

Connect

#1 wire from the

RELAY OUTPUT

terminals on the keypad to

CYCLE terminal on the

gate opener control board.

Connect

#2 wire from the

RELAY OUTPUT terminals

on the keypad to the

COM

terminal on the gate opener

control board.

#1

#2

GTO/PRO GP-SL100 and GP-SW100

Control Boards

3. Test Keypad

Turn the gate opener power switch to ON. Test the keypad by entering “1234.”