Dip switches, Main dip switch settings (modes), Pull-push mode1 mode2 lock/beacon – Mighty Mule FM352 User Manual

Page 30

Advertising
background image

26

M i g h t y M u l e 3 5 2

DIP Switch #4 - Lock/Beacon

This DIP selects the mode of operation of the "AUX OUT" terminal. The OFF (factory) setting is selected

when the Mighty Mule Automatic Gate Lock is used with the Mighty Mule 352. The RED wire from the

lock is connected to the "AUX OUT +" terminal and the BLACK wire from the lock is connected to the

"AUX OUT –" terminal. Factory default-(OFF position provides a timed pulse of voltage to the accessory

while the gate opener is activated). Lock and circuit board will be damaged if #4 is on.

The ON setting is selected when a beacon or light is used with the Mighty Mule 352. One wire from the

low voltage beacon or light is connected to the "AUX OUT +" terminal and the other to the "AUX OUT –"

terminal. (ON position provides a continuous voltage to the accessory while the gate opener is activated).

Important: Make sure your light or beacon is a 12Vdc system that draws less than 2 amps or less than 25 watts.

1

ON

2

3

4

15

CHARGING
POWER

STATUS

RF

PULL-PUSH
MODE1
MODE2
LOCK/BEACON

OFF

120

MIN

MAX

STALL FORCE

CLOSE TIME

SET

LIMIT

LEARN

REMOTE

AUX OUT

SOLAR

PANEL

18VAC

RCVR

GRN

BLK

RED

EXIT

SAFETY

EDGE

CY

CLE

COMMON

LINK

1

ON

2

3

4

PULL-PUSH
MODE1
MODE2
LOCK/BEACON

MODE 1

MODE 2

* MODE1 or MODE 2 must be in the ON position to operate in DUAL mode.

DIP #2 DIP #3 Dual Mode Sequence
OFF

OFF

Single Gate Mode

ON

OFF

MASTER opens 1st, SECOND opens 2 seconds later.

SECOND closes 1st, MASTER closes 4 seconds later. (factory)

OFF

ON

MASTER opens 1st, SECOND opens 2 seconds later.

SECOND closes 1st, MASTER closes 8 seconds later.

ON

ON

MASTER and SECOND simultaneously open and close.

1

ON

2

3

4

15

CHARGING
POWER

STATUS

RF

PULL-PUSH
MODE1
MODE2
LOCK/BEACON

OFF

120

MIN

MAX

STALL FORCE

CLOSE TIME

SET

LIMIT

LEARN

REMOTE

AUX

OUT

SOLAR

PANEL

18VAC

RCVR

GRN

BLK

RED

EXIT

SAFETY

EDGE

CY

CLE

COMMON

LINK

Low Voltage Wire
from Solar Panel(s)

RED

BLK

Master Control Board Settings

Connecting Solar Panel(s)

IMPORTANT: Never connect the transformer and a solar panel

to the opener control board at the same time. It will damage the

control board.

If you are using the transformer included with the Mighty Mule

352 to charge the opener battery, skip this section and go to

"MASTER CONTROL BOARD SETTINGS" below.

Strip

3

/

16

" off the ends of the low voltage wire from

the solar panel and twist tightly. Attach

the RED solar

panel wire to the SOLAR terminal marked

(+)

and the

BLACK solar panel wire to the SOLAR terminal marked

(–)

on the

MASTER control board.

Tighten set screws against exposed end of wires. A dab
of household petroleum jelly on each terminal will help
prevent corrosion.

NOTE: For multiple panels wire the panels in parallel as
shown in this diagram.

RED

RED

BLACK

BLACK

attach BLACK to negative (–) solar terminal on control board

attach RED to positive (+) solar terminal on control board

Solar Panels connect in PARALLEL

DIP Switches

Main DIP Switch Settings (MODES)

DIP Switch #1 - Push/Pull-to-Open

If your gates open into the property the DIP Switch

is set to OFF (factory default). If your gates open out

from the property the DIP Switch must be set to the

ON position. NOTE: if you have a Push-to-Open gate

application you will need Push-to-Open brackets

(see Push-to-Open Instructions on page 36).

Advertising