Palruf® technical guide greca 70 – Palram PALRU User Manual

Page 2

Advertising
background image

PALRUF® Technical Guide

Greca 70

©PALRAM Industries. All rights reserved.

Updated:

27/10/2008

Curved Roof Fastening

ƒ

Minimum curving radius along the corrugations - 4.0 m

Roof and Wall Positioning and Fastening

ƒ

Start fastening the screws on the Side lap where the Palruf sheet Over-lap the previously installed

sheet.

ƒ

Fasten the screws on the lower edge purlin, each second corrugation crest, starting at the same

side.

ƒ

Fasten at the internal purlins, at each third corrugation crest.

ƒ

Fasten the screws at the upper edge purlin, at each second crest, starting at the same side.

ƒ

Wall mounting (cladding) – the same as roofing.


External Purlin Fastener location

Internal Purlin Fastener location

Side-Lap

ƒ

Use tow corrugations side-lap where the slope smaller than 10%, long span and large rain loads.

ƒ

Start from the side where the PALRUF sheets overlap on top of the other sheet.

ƒ

Apply sealing tape along the crest centerline.

ƒ

Use sheet to sheet (stitching) fasteners between the purlins, every 300-400 mm .

End-Lap

ƒ

Maximum overhang up to 100 mm from screw centerline.

ƒ

Minimum overhangs 50 mm from screw centerline.

ƒ

Apply sealing strip along screws centerline.

ƒ

Roof edge – not more than 100 mm

Stitching Screw

ƒ

Stitching screws are needed for improving side lap sealing in cases of slope smaller than 10%, long

spans and large rain loads.

Advertising