Floor Stand Reactors

P a r r I n s t r u m e n t C o m p a n y

4

Explanation of Symbols

II

On position, full power heater switch

I

On position, half power heater switch

O

Off Position

~

Alternating Current (AC)

This CAUTION symbol may be present on the Product Instrumentation
and literature. If present on the product, the user must consult the ap-
propriate part of the accompanying product literature for more infor-
mation.

This CAUTION symbol indicates that the surface may be hot.

Protective Earth (PE) terminal. Provided for connection of the Protec-
tive Earth (green or green/yellow) supply system conductor.

Environmental Conditions

This instrument is intended to be used indoors.

Operating: 5 ºC to 35 ºC; maximum relative humid-
ity of 80% non-condensing. Installation Category II
(over voltage) in accordance with IEC 664.
Pollution degree 2 in accordance with IEC 664.

Altitude Limit:

0 to 6000 feet above sea level.

Storage: -25 °C and 65 °C; 10% to 85% relative hu-
midity.

Provisions for Lifting and Carrying

The 4530 Floor Stand Reactors and its components
are very heavy. Before moving ensure all cables are
disconnected. Use proper and safe lifting techniques
when installing or moving the 4530 Reactor and/ or
its components.

Caution!

Do not use in hazardous atmospheres.

Intended Usage

This system has been designed for use as a high
pressure reactor system. It has been designed, built,
and tested to strict physical and electrical standards.
However, it is the user’s responsibility to install and
operate it in conformance with local pressure and
electrical codes.


If this equipment is used in a manner beyond its in-
tended usage, the protection provided by the equip-
ment may be impaired.

Cleaning & Maintenance

Periodic cleaning may be performed on the exterior
surfaces of the instrument with a lightly dampened
cloth containing mild soap solution. All power
should be disconnected when cleaning the instru-
ment.

There are no user serviceable parts inside the prod-
uct other than what is specifi cally called out and
discussed in this manual. Advanced troubleshooting
instructions beyond the scope of this manual can
be obtained by calling Parr Instrument Company in
order to determine which part(s) may be replaced or
serviced.

Ensure that any hot surfaces have had

adequate time to cool before cleaning

or maintaining the reactor and/or its

components.