Specifications – Rupert Neve 551 - 500 Series Inductor EQ User Manual

Page 6

Advertising
background image

LF

Adjusts up to 15 dB of boost or cut at the selected low frequencies. Cut can be used
as a variable, and perhaps more gentle alternative to using the HPF.

OUTPUT

The main output signal comes from the output transformer secondary which is
balanced and ground free. A ground free connection guarantees freedom from
hum and radio frequency interference when connected to a balanced destination.

POWER

+/- 16V supplied by 500 series rack

Specifications

Equalizer Bypassed

Noise:

Measured at Main Output, un-weighted, 22Hz-22kHz, source impedance 40 Ohms
balanced.

Better than -102dBV

Frequency Response

Main output, no load

+/- 0.1dBu from 20Hz to 31.5kHz

-1dB @ 120kHz

Maximum Output Level

23.25dBu

Total Harmonic Distortion and Noise

@ 1kHz, +20dBu output level, no load.

Better than 0.0025%

@ 20Hz, +20dBu output level, no load.

0.13% Typical (2nd and

3rd harmonic)

High Pass Filter:

-2.7dB @ 80Hz

Slope:

12dB/Octave

Equalizer Engaged

Noise:

Measured at Main Output, un-weighted, 22Hz-22kHz, source impedance 40 Ohms
balanced.

Better than -94dBV

Frequency Response

Main output, no load

+/- 0.25dBu from 20Hz to 45kHz

-2dB @ 120kHz

Maximum Output Level

23dBu

Advertising