Total Harmonic Distortion and Noise

@ 1kHz, +20dBu output level, no load.

Better than 0.009%

@ 20Hz, +20dBu output level, no load.

0.13% Typical (2nd and

3rd harmonic)

Power Requirements

120mA on +16VDC

110ma on -16VDC

Low Frequency EQ

Color

Sweep Trace

Comment

1

1

Red

EQ Flat

2

1

Cyan

35 Hz Full Boost

3

1

Cyan

35 Hz Full Cut

4

1

Green

60 Hz Full Boost

5

1

Green

60 Hz Full Cut

6

1

Magenta

100 Hz Full Boost

7

1

Magenta

100 Hz Full Cut

8

1

Red

220 Hz Full Boost

9

1

Red

220 Hz Full Cut

-20

+20

-15

-10

-5

+0

+5

+10

+15

d

B

u

10

200k

20

50

100 200

500

1k

2k

5k

10k 20k

50k

Hz