Simaudio Neo 340i Integrated Amplifier User Manual

Page 11

Advertising
background image


340i Integrated Amplifier

____________________________________________________________________________________

11

Internal Settings


We strongly recommend that you ask your
MOON Authorized Dealer to make these

adjustements. If you decide to do this on your

own, any damage cause to this component,

including from static discharge, will not be

covered under warranty.

There are three (3) types of settings available on the
optional phono section of the Nēo 340i;

Capacitance loading, Resistance loading, and Gain

level. Each setting is adjustable through the use of

jumpers. For each type of setting, there are 2 banks

of jumpers – one each for the left and right

channels. This is the result of the phono section’s

genuine mirror-image circuit design which yields
exceptional stereo separation.

Always disconnect all audio connections and the AC

power cord of your Nēo 340i prior to changing any

of the following input settings.

There are six (6) screws, located on the top of the

chassis, that you must remove using a phillips head

screw driver. Once these screws are removed,

carefully lift off the chassis cover. Once the cover is

removed, you are ready to make all of the necessary
internal adjustments to the 340i phono module to

achieve optimal sonic performance.


Resistance Loading:

There are two (2) different settings available for
setting the resistive load; 100

Ω and 47kΩ which are

represented by jumper sockets R9 for the left
channel and jumper socket R24 for the right channel

(refer to figure 2 – section labeled “LOADING”). The
factory default setting is 47k

Ω, therefore both

jumpers will be found in each of the two left most

sockets.

For moving magnet (MM) cartridges, it is

recommended that you leave the jumpers inserted
in the factory default setting of 47k

Ω. Conversely, if

you’re using a moving coil (MC) cartridge, you
should use the 100

Ω jumper settings by simply

inserting the supplied jumpers into each of the two

right-most sockets of jumpers R9 and R24.

Capacitance Loading:

There are two (2) different settings available for the

capacitive load; 0pF and 100pF which are
represented by jumper sockets C9 for the left

channel and jumper sockets C17 for the right

channel (refer to figure 2 – section labeled

“LOADING”). The factory default setting is 100pF for

a moving magnet cartridge, therefore both jumpers

will be found in each of the two right most sockets.

For MM cartridges, it is recommended that you leave

the jumpers inserted in the factory default setting of
100pF. Conversely, if you’re using a MC cartridge,

you should use the 0pF jumper settings by simply

inserting the supplied jumpers into each of the two

left-most sockets of jumpers C9 and C17.

Gain Level:

There are two (2) different settings available for
gain level. They are 40dB for MM cartridges and

60dB for MC cartridges, which are represented by

jumper socket J17 for the left channel and jumper

socket J22 for the right channel (refer to figure 2 –

section labeled “GAIN”). The factory default setting

is for a MM cartridge , therefore both jumpers will

be found in each of the two right most sockets
labeled MM;

It is highly recommended that you

do not use the jumpers labeled MC for an MM

cartridge as this will overload the 340i

. When

using a MC cartridge, you should insert the supplied

jumpers into each of the two left-most sockets

labeled MC.

Advertising