Rear panel – Sonodyne AMC+120P User Manual

Page 5

Advertising
background image

CLASS 2 WIRING

Audio Amplifier

Model: AMC+120P

Rated Value:

115V~60Hz 460W

230V~ 50Hz 460W

Manufacture Date:

Made In China

CERTIFIED TO

CAN/CSA STD.C22.2

No.60065

CONFORMS TO

ANSI/UL SYD.60065

230 V. FUSE T2AH 250V

115 V. FUSE T4AH 250V

1

3

2

4

5

1

Input

These 3 pin XLR sockets accept the source input for each
channel. One input is a male XLR, the other is a female
XLR. The male XLR is normally used as a thru output. When
wiring from unbalanced sources, pins 1 and 3 should be
shorted together. The input sensitivity (voltage required to
drive amplifier to maximum power) of the amplifier is 150mV
(-14dBu) with the Input Level Control set at maximum.

2

Level

This pot controls the level of the signal through the amplifier
channel. Minimum position is Off and maximum gives a
sensitivity of 150mV (-14dBu). The maximum input voltage
before the input stage clips is 2.45V (+10.0dBu). Depending
on the input source, the input level control should be run
above the 12 o’clock position (half way) to avoid clipping the
input stage.

3

Direct Out

Speaker connections are provided on screw terminals.

4 ohm low impedance, 70V and 100V line outputs are
provided.

Direct Out continued
Minimum Impedance

AMC

+

120P AMC

+

250P AMC

+

1202P

Distributed Line Output
70V

41 ohm

20 ohm

41 ohm

100V

83 ohm

40 ohm

83 ohm

Low Impedance Output
(both versions)

4 ohm

4 ohm

4 ohm

NOTE: Only connect one output – either Distributed Line or Low Impedance per channel.
Do not connect 4 ohm and 70 V / 100 V at the same time.

The output strip comes fitted with a touch-proof cover held in place by two M3 machine screws
with flat and spring washers.

4

IEC Mains Input Socket

This is a standard IEC 3 pin socket. It accepts a standard IEC mains cable, provided. The fuse
drawer at 5 contains the mains fuse and a spare. The mains fuse is a time lag (slow blow)
HRC 20mm x 5mm ceramic type fuse.

Ratings

AMC+120P AMC+250P AMC

+

1202P

230V operation

2A

4A

4A

115V operation

4A

8A

8A

Always replace the fuse with one of the same value and type.

Always disconnect power to the amplifier before replacing fuses.

5

Mains Voltage Selector

The operating voltage of the amplifier is user selectable between for 115V or 230V operation
via a slide switch located above the AC mains inlet. This switch should be set to match the AC
voltage of your country.

Failure to set the Mains Voltage Selector correctly prior to use will

result in catastrophic failure.

These terminals are hazardous. External wiring to these
terminals requires installation by a professional.

AMC+120P shown here

PAGE 5

AMC

+

SERIES INSTALLATION AND OPERATION MANUAL

REAR PANEL