background image

100V Line

70V Line

4 ohm voice-coil

P

P

P

P

P

P

(Per Channel)

(Per Channel)

OUTPUT

DISTANCE

WIRE SIZE

AMC+120P / AMC+1202P

AMC+250P

100V

Up to 50m

AWG24(0.2mm2)

AWG22(0.35mm2)

50m–200m

AWG18(0.75mm2)

AWG16(1.5mm2)

Over 200m

AWG16(1.5mm2)

AWG13(2.5mm2)

70V

Up to 50m

AWG22(0.35mm2)

AWG18(0.75mm2)

50m–200m

AWG16(1.5mm2)

AWG13(2.5mm2)

Over 200m

AWG13(2.5mm2)

AWG10(6.0mm2)

4 ohm

Up to 10m

AWG18(0.75mm2)

AWG18(0.75mm2)

10m–30m

AWG13(2.5mm2)

AWG13(2.5mm2)

Over 30m

Not Recommended

Not Recommended

NOTE: Only connect one output – either Distributed Line or Low Impedance.

Line Output
The LINE output XLR can be used to connect up to 6 booster amplifiers. Balanced wiring
(shielded pair cable) is recommended.

NOTE: When wiring the LINE output as unbalanced, pin 2 should be wired as hot and pin 1
should be wired as ground/shield. Do not wire pin 3.

Input Connections
For wiring balanced in, pin 2 is hot.
Balanced input wiring (shielded pair cable)
is recommended. Unbalanced RCA wiring
should be keep as short as possible.

Direct Output
The output terminal strip accepts wire sizes from 16-22AWG (1.5mm2 –
0.35mm2) or spade lugs. The following table should be used as a guideline
for cable sizes. Regulations in your area may require different gauged wire
and should be checked before using.

PAGE 7

AMC

+

SERIES INSTALLATION AND OPERATION MANUAL

INSTALLATION

Advertising