Tep 6, Onnect, Lectricity (for – Southbend P32N-TT User Manual

Page 28: Ections with, Ases), Tep 7, Upply

Advertising
background image

P

LATINUM

S

ERIES

R

ANGE

PAGE

28

OF 47

OWNER’S MANUAL 1185836 REV 8 (9/14)

4. Attach each wall shield to the back of the corresponding flue riser using the provided #10 sheet metal screws.
5. Connect the top side edges of adjoining flue risers using the provided small plates and screws.
6. If tubed shelves were installed, place the tubes in place in the shelf brackets.
7. If sloped enclosures were ordered (for flue-mounted salamander broilers and/or cheese melters), install them at

this time.

S

TEP 6:

C

ONNECT

E

LECTRICITY (FOR

S

ECTIONS WITH

O

VEN-

B

ASES)

A wiring diagram is located behind the kick panel of the oven-base ranges. Be sure that the input voltage and phase

match the requirements shown on the serial plate.
Oven-base ranges ordered with a 115V, 60Hz, single-phase electrical rating are factory-supplied with a three-wire cord

with a three-prong plug that fits any standard three-prong grounded receptacle. Each standard oven requires a 15 ampere

supply, while each convection oven requires a 20 ampere supply.
Oven-base ranges ordered with a 208/236V, 60Hz, single- or three-phase electrical rating are factory-equipped with a

two-pole terminal block located behind cover plate located on the rear of the unit. To connect the supply wires, remove

the cover plate. Route the supply wires and the grounding wire through the strain relief fitting to the terminal block. Insert

the supply wires, one each, into the two poles of the terminal block and tighten the screws. Insert the ground wire into the

grounding lug and tighten the screw. Re-attach the cover plate.
Three phase units are wired as above, using only two supply wires. The third wire is not used and must be properly

terminated.
All units are shipped wired as specified by factory order. Conversion between single-phase and three-phase can be

accomplished by referring to phase loading and line amperes chart on the wiring diagram for wire size and ampere

requirements.

S

TEP 7:

C

ONNECT

G

AS

S

UPPLY

If the sectional range is being installed at over 2,000 feet altitude and that information was not specified when ordered,

contact the appropriate authorized Southbend Service Representative or the Southbend Service Department. Failure to

install with proper orifice sizing will result in poor performance and may void the warranty.
The sectional range is design-certified for operation on natural or propane gases. The sectional range is shipped

configured and adjusted for the type of gas specified by the purchaser, which is indicated on the serial plate (see Figure 1

on page 3). Connect the sectional range ONLY to the type of gas for which it is configured and adjusted.
Minimum supply pressure is 7” W.C. for natural gas, 11” W.C. for propane. An external pressure regulator and shut off

valve are provided. If using a flexible-hose gas connection, the I.D. of the hose must not be smaller than the connector on

the sectional range, and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent undue strain

on the gas connection.
If applicable, the vent line from the gas pressure regulator shall be installed to the outdoors in accordance with local

codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code,

CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for

satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and

affect burner operating characteristics. A 1/8” pressure tap is located on the manifold to measure the manifold pressure.

The supply line to the sectional range should be no smaller than the inside diameter of the pipe on the sectional range to

which it is connected.

CAUTION

ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE ONLY SOAPY

WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. ALL

CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE APPLIANCE HAS BEEN PUT INTO OPERATION.

TEST PRESSURE SHOULD NOT EXCEED 14” W.C

Do the following to connect the gas supply:

1. Check that all control knobs on the sectional range are in the OFF position.
2. Purge the gas supply line to clean out dust, dirt, or other foreign matter before connecting the line to the sectional

range.

I

NSTALLATION

Advertising
This manual is related to the following products: