Peration – Southbend P32N-TT User Manual

Page 7

Advertising
background image

P

LATINUM

S

ERIES

R

ANGE

OWNER’S MANUAL 1185836 REV 8 (9/14)

PAGE

7

OF 47

O

PERATION

DANGER

EXPLOSION HAZARD

In the event a gas odor is detected, shut down equipment at the main shut off valve. Immediately call the emergency

phone number of your gas supplier.

CAUTION

If a pilot flame pilot should go out, the flow of gas to the corresponding burner is NOT interrupted. Consequently, it

is the responsibility of the operator to check the ignition of each burner immediately EVERY TIME a burner is turned

on. Should ignition fail after 10 seconds, turn off the burner, wait 5 minutes, and then try again.

L

IGHTING

A

FTER

G

AS

H

AS

B

EEN

S

HUT

O

FF

When turning on the main gas supply to a sectional range, do the following:

1. Make sure that all the control knobs and power switches of all the connected appliances are in the OFF position.
2. Turn on the gas-supply shut-off valve(s).
3. Light the standing pilots of each connected appliance.
4. Light the ovens of the sectional range first, then wait six minutes before turning on the top sections.

This enables all air to be purged from the sectional-range gas piping.

SHUTDOWN OF ENTIRE RANGE

To place the range in a standby state (ready for use), Oven bases with the electronic ignition option, turn all burner

control knobs to OFF, set all thermostats to their lowest position, and switch all ovens OFF. The pilots will remain lit.

On the standing pilot units, same as above except turn thermostat knob to the “OFF” position. The pilots will remain lit.
To completely shut down the range for an extended period (or prior to disconnecting the gas supply), place the range

in a standby state (as described in the previous paragraph), then turn OFF the manual shut-off valves of all gas supply

connections. This will extinguish the pilots.