INSTALLATION AND OPERATION MANUAL,

ELECTRIC COUNTER CONVECTION STEAMER, MODEL R18A-4

MANUAL 1195734 REV0 (11/22/2011) 6 HEAVY DUTY STEAM

LEVELLING

Using a spirit level or pan of water in the bottom of the steamer, adjust the levelling feet or the

feet on the adjustable legs to level the steamer front-to-back and side-to-side. After the drain is

connected, check for level by pouring water onto the floor of the compartment. All water should

drain through the opening at the back of the compartment cavity.

ANCHORING STEAMER (Without Legs)

1. Place steamer in the desired location on the levelled counter top and mark four corners.

Remove the steamer and drill ½" holes as indicated in Figure 1.

2. Apply a bead of RTV or other equivalent sealant around bottom perimeter edge of the

steamer. If anchoring the steamer, this bottom seal is necessary to meet NSF

requirements.

3. Set steamer on counter and bolt down securely with 3/8 - 16 bolts (not supplied).

STACKING KIT

Follow instructions in the stacking kit when installing stacked convection steamers.