Southbend R24-5 User Manual

Page 21

Advertising
background image

INSTALLATION AND OPERATION MANUAL,

ELECTRIC COUNTER CONVECTION STEAMER, MODELS

R24-3, R24-5

MANUAL 1195730 REV0 (11/22/2011) 21 HEAVY DUTY STEAM

REMOVAL OF SCALE DEPOSITS (Continued)

WARNING: Read and follow instructions on the CLR bottle. Use
plastic or rubber gloves to avoid skin contact. If CLR comes in
contact with skin, rinse with clean water.

1. Drain steam generator by setting the main power switch to OFF. Set cooking time to “0".

2. Set the main power switch to DELIME.

3. Delime port (A) is located on left side at the rear of the unit. Unscrew hex plug from elbow

to allow CLR solution to be poured in using a tube and funnel. Pour in 28 ounces of solution
into the generator (pour slowly to avoid spillage). Remove tube and funnel.

4. Screw the hex plug back into the elbow so that it is sealed.

5. Turn main power switch to ON.

6. Allow steamer to remain in READY cycle for 1-1/2 hours, then turn main power switch OFF

and allow generator to drain.

7. FLUSH CYCLE: Turn main power switch to ON. When READY light comes on, turn main

power switch to OFF to flush generator. Repeat this step three times to completely flush
generator.

8. Clean exterior and interior. Use a mild solution of soap and water. Rinse with clean cloth.

Dry with soft cloth. Leave compartment door open when not in use.

The steamer is now ready for use. Turn off for overnight shutdown.

Advertising
This manual is related to the following products: