INSTALLATION AND OPERATION MANUAL,

ELECTRIC COUNTER CONVECTION STEAMER, MODELS SX-3, SX-5

MANUAL 1195730 REV0 (11/22/2011) 5 HEAVY DUTY STEAM

2.0 INSTALLATION INSTRUCTIONS

GENERAL

The SX-3 and SX-5 steamers are single compartment electric pressureless steam cookers with
an internal electric steam generator that maintains water temperature at approximately 205°F.
SX-3 is rated 7.5 kW as standard; 10 kW is optional. SX-5 is rated 12 kW as standard; 15 kW
is optional.

At high altitude locations a lower temperature is required to achieve atmospheric steaming.
Contact your authorized service office to have the thermostat adjusted if the steamer will be
operated at high altitudes.

INSTALLATION

UNPACKING

Immediately after unpacking the steamer, check for possible shipping damage. If the steamer
is found to be damaged, save the packaging material and contact the carrier within 15 days of
delivery.

Prior to installation, verify that the electrical service agrees with the specifications on the
machine data plate which is located on the left side panel.

LOCATION

Allow space for plumbing and electrical connections. Allow adequate access for operating and
servicing the steamer (36" at the front of the steamer and 15" above the steamer).

LEGS (OPTIONAL)

If the optional 4" adjustable legs are used, remove the four levelling feet on the bottom of the
steamer.

LEVELLING FEET (Standard) OR 4" ADJUSTABLE LEGS (Optional)

Thread the four 2" levelling feet shipped in a bag inside the steamer cabinet into the threaded
holes on the bottom corners of the steamer. Or, thread the four optional 4" adjustable legs into
the threaded holes on the bottom corners of the steamer.