Hence, there is not a right or wrong position for a ground lift switch. If
either position improves an otherwise hummy-buzzy situation, that is the
right position.




















The ASC with the optional transformer gives you two choices of
balanced outputs; electronic active balanced at the 1/4” TRS jack or
transformer balanced at the XL connector. On the Model ASC-T, the
transformer is wired only to the XL connector and the balanced active
output is wired only to the to the 1/4” TRS jack.

To prevent the transformer from interacting with the electronic active
output circuit, the XL output is automatically disabled when the 1/4”
TRS output jack is used on the ASC-T version.

This connector will accept the 4 pin rectangular plug of the power
module cable. This connector and respective plug are keyed so they will
fit in only one direction. For installation instructions refer to
"Connecting the Power Module" as described in Chapter 2.


For installations where the ASC is subject to extreme vibration or
movement, the wire tie holder may be used to secure the power cable.

20. Power Supply Connector

21. Wire Tie Holder

Chapter 3 Operation Section

19

21

20

USE WITH SPECK

PRODUCTS ONLY

speck

electronics

Model ASC - 4 Band Equalizer

OUTPUT TRANSFORMER OPTION

Fallbrook, California

S/N

POWER

AUX DC I/O

USE WITH PS-4

POWER MODULE

19. Transformer Option

(for Model ASC-T only)