Spectrum Controls 1756sc-OF8H Series A User Manual

Page 150

Advertising
background image

Module Scan Time for all Channels—

Analog

12ms minimum floating point

HART (Typical)

6.4 seconds with 4 variables

12 seconds with 8 variables.

Isolation Voltage

2550VDC terminal block to backplane for 1 second.

2550VDC Channel to Frame Ground for 1 second.

Module Conversion Method

R-Ladder DAC

RTB Screw Torque (NEMA)

7-9 inch-pounds (0.8-1Nm)

Module Keying (Backplane)

Electronic

RTB Keying

User defined

Field Wiring Arm and Housing

20 Position RTB (1756-TBNH or TBSH)1

Environmental Conditions

Operating Temperature

0 to 60°C (32 to 140°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Relative Humidity

5 to 95% noncondensing

Regulatory Compliance

UL 508

CSA (Class 1, Div 2, Group A,B,C,D)

CE compliance to EN 61010-1 and EN 61131-2

FM (Class 1, Div 2, Group A,B,C,D)

Firmware Revision History

Revision No.

Description

1.1

New

2.3

Updated to provide user selectable pass through queue servicing speed.

Advertising
This manual is related to the following products: