2 fibre params – StorCase Technology InfoStation 10-Bay 1U Ultra320/SATA User Manual

Page 74

Advertising
background image

InfoStation 10-Bay RAID User's Guide - Rev. E00

StorCase Technology, Inc.

RAID Controller Configuration

61

2 Fibre Params

(For FC-to-SATA versions only)

NOTE:

Configuration changes made in the Fibre Params menu must be saved and the
RAID controller restarted before changes can take effect. Refer to section "5
NVRAM
" of this User's Guide for further information.

2 Fibre Params

2.1 Primary FC

2.1.1

Enable Hard

Loop ID

2.1.2

Set Hard

Loop ID

2.1.3

Set Connection

Mode

2.1.4

Set Data Rate

2.2 Secondary

FC*

2.1.5

LUN Map

* Submenus are the same

as 2.1 Primary FC

2.3 SAN Mask

1Gbit / 2Gbit /

Auto-Negotiated

Match slices in

existing arrays

(up to 16 LUNs)

Arbitration Loop /

Point-to-Point

2.3.1

Visible For

All Hosts

** Submenus are the same

as 2.3.2.1 Port 1

2.3.2

SAN Mapping

Enable / Disable

Enable / Disable

Enable / Disable

2.3.1.1 Port 1

2.3.1.2 Port 2

2.3.2.1 Port 1

2.3.2.2 Port 2**

2.3.2.1.1 - 2.3.2.1.8

Select Host

Select LUN

2.3.3.1 - 2.3.3.8

Select Host

2.3.3

Edit WWN

Table

2.3.4

View WWN

Table

2.3.5

View SAN

Mapping

2.3.5.1 Port 1

2.3.5.2 Port 2

Yes / No

2.1 Primary FC

This function enables the user to configure Primary FC settings.

2.1.1 Enable Hard Loop ID

Select either Enable or Disable (default). Enable allows the user to set the ID manually. Dis-
able allows the controller to set the ID.

2.1.2 Set Hard Loop ID

Enter the Hard Loop ID for this controller (Hard Loop ID must be enabled).

Advertising
This manual is related to the following products: