Rear panel – StorCase Technology InfoStation 12-Bay 4U Ultra160/SATA User Manual

Page 17

Advertising
background image

6

Introduction

StorCase Technology, Inc.

InfoStation 12-Bay RAID User's Guide - C00

Rear Panel

(Figure 3)

NOTE:

Blank plate (provided) must be installed if any module slot is left empty. Instal-

lation of the blank plate is necessary for proper cooling inside chassis.

•

UI Module - LED panel displays system statuses, alarms, and warnings. Refer to

section "User Interface Module" for further information.

•

I/O Panel - Provides two (2) DB9 connectors for RS-232 and Modem, and two (2)

HD68 I/Os for SCSI Host channels (SCSI-to-SATA version only) or two (2) FC ports

for dual FC-ALs (FC-to-SATA version only). Also provides space for up to four (4)

extra I/Os if desired.

•

Power Supply Module(s) - Two (2) 460W redundant, hot swappable power

supply modules. Each module features overvoltage and overcurrent protection, total

usage hours, and power supply fault detection.

Module LED(s) -

Green LED -

Steady glow indicates normal power supply operation.

No glow indicates no A/C power.

Red LED -

Steady glow indicates either:

Power supply failure.

or

A/C cord is plugged in, but power switch is in the OFF position.

WARNING:

DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These

handles are specifically designed for the installation and re-

moval of modules only!

Power Switch(es) - Rocker switch(es) control power to the power supply

module(s).

A/C Power In - Accepts U.S. and other available international standard power

cables.

•

Fan Module(s) - Two (2) redundant, hot swappable fan modules. Each module

contains two (2) high-pressure, variable-speed fans for ample chassis cooling (160

CFM per module).

•

Module Option - Allows the installation of StorCase upgrade products such as an

optional SNMP upgrade module. Contact StorCase for further information.

Advertising