Scsi problems – StorCase Technology InfoStation 12-Bay 4U Ultra160/SATA User Manual

Page 72

Advertising
background image

InfoStation 12-bay RAID User's Guide - Rev. C00

StorCase Technology, Inc.

Appendix C - Troubleshooting61

SCSI Problems

(For SCSI-to-SATA version only)

•

The RAID Controller is not properly identified by the SCSI adapter during

initialization of the computer system.

Cause - SCSI ID set for the RAID Controller could be the same ID used by another SCSI device

attached to the same SCSI host adapter.

Fix -

Select a different SCSI ID for the RAID Controller. Most SCSI host adapters provide

onboard ROM BIOS (or software utility) that displays attached devices and their SCSI

IDs. Disconnect the RAID Controller from the SCSI host adapter during system boot

and note the SCSI IDs already in use.

•

The RAID Controller is identified at all SCSI IDs.

Cause - SCSI ID set for the RAID Controller could be identical to the reserved SCSI ID used

by the SCSI host adapter.

Fix -

Configure the RAID Controller to a different SCSI ID. Most SCSI host adapters reserve

SCSI ID7.

•

The RAID Controller is not detected by the SCSI host adapter.

Cause - Incorrect termination in the daisy-chain configuration, or possibly a loose SCSI

cable.

Fix -

For daisy-chain configurations, verify that only the SCSI host adapter and the last

SCSI device is terminated.