Tube Tech CL 1B Opto Compressor User Manual

Page 3

Advertising
background image

LYDKRAFT ApS

Mose Allé 20, DK 2610 Rødovre

Denmark

3

CONTROLS:

GAIN:

The gain control is used to "make up" for the gain loss, which takes place
when the unit is compressing. It is placed after the gain-reduction circuit
and therefore has no influence on the threshold setting. The gain-control is
continuously variable from off to +30 dB.

RATIO:

The ratio control varies the ratio by which the input signal is compressed.
If the ratio selected is to 2:1, and the input signal increases 10 dB, the
output signal is only increased by 5 db. The ratio control is continuously
variable from 2:1 to 10:1.

THRESHOLD:

The threshold is the point where the compressor begins its action. It is
defined as the point where the gain is reduced by 1 dB.
The threshold is continuously variable from +20dBU to -40 dBU.

METER:

The VU-meter switch has three positions:

1.

Input

The meter is reading the level at the input socket.

2.

Compression

The VU-meter is reading gain reduction.
Its rest position is "0 VU", and the amount of
compression is shown as a decreasing deflection in
dB.

3.

Output

The VU-meter is reading the level at the output socket.
"0 VU" is equivalent to +4 dBU.

NB:

Leave the meter switch in position compression as it might
introduce distortion if left in the input or output position.

IN/OUT:

This leverswitch switches the compressor in and out of the signal path. The
out position bypasses the entire compressor.

ATTACK:

The attack control chooses how fast/slow the compressor responds to an
increase in the input signal.
The attack control is continuously variable from 0.5 to 300 milliseconds.

RELEASE:

The release control chooses how fast/slow the compressor responds to a
decrease in the input signal.
The release control is continuously variable from 0,05 to 10 seconds.

(980112)

Advertising