ADJUSTMENT OF THE VU METER READING "COMPRESSION":

1)

Turn the THRESHOLD-control fully counter-clockwise.

2)

Switch the METER-selector to Compression.

3)

Set the RATIO-control at 2:1

4)

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.

5)

Adjust the GAIN-control to an output-reading of 0,0 dBU.

6)

Adjust P 4 (P 2)* until the meter is reading 0 VU.

7)

Apply a DC-voltage of +250,0 mV into the side chain jack socket and observe that the
output level has dropped to -10,0 dBU. If this is not the case, adjust the compression
tracking (see above)

8

Adjust P 3 until the meter is reading -10,0 VU.

9)

Remove the DC-voltage from the side chain jack socket.

10)

Repeat step 6 - 9.

NB:

The VU-meter accuracy should be within +/- 0,5 dB when reading compression.

ADJUSTMENT OF THE RELEASE CONTROL:

1)

Set the METER switch in position compression.

2)

Set the attack/release SELECT switch in position manual.

3)

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.

4)

Adjust the THRESHOLD-control to a reading of -10 VU of the

VU-meter

5)

Set the ATTACK-control at fast.

6)

Set the RELEASE-control at slow.

7)

Switch off the 1 kHz and observe that the VU meter moves to 0 VU in approx. 10 sec.

8)

If this is not the case, adjust P 1 (P 5)*, to obtain a release time of approximately 10 sec.

*

The trimpots in parenthesis refers to PCB 870316-0,1,2

(