LYDKRAFT ApS

Mose Allé 20, DK 2610 Rødovre

Denmark

5

ADJUSTMENT PROCEDURE:

CAUTION:

Before making any adjustment let the unit heat-up at least 15 min.
Observe that the offset-voltage measured at the sidechain jack socket, when the
THRESHOLD is off, is not greater than +/- 15 mV DC in both position "fixed" and
"manual".
(tip is link 1 and ring is link 2).

If the voltage exceeds this value, replace either IC1 or IC2.

THE GRE (GR1) SHALL BE MARKED FROM 1.005 TO 1.175

ADJUSTMENT OF BASIC GAIN:

1)

Apply a signal of 1 kHz, -10,0 dBU into the input of the compressor.

2)

Turn the GAIN-control fully clockwise.

3)

Set the RATIO-control at 1,5:1

4)

Adjust the pre-set GAIN (

P1/P101 located

on amp/psu PCB) to an output-reading

of 0,0 dBU.

ADJUSTMENT OF COMPRESSION TRACKING:

1)

Turn the THRESHOLD-control fully counter-clockwise.

2)

Set the RATIO-control at 1,5:1.

3)

Set the LINK-switch at link 1.

4)

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.

5)

Adjust the GAIN-control to an output-reading of 0,0 dBU.

6)

Apply a DC-voltage of +250,0 mV into the sidechain jack socket (tip) and observe that
the output level has dropped to -10,0 dB.

7)

If this is not the case, adjust the level with P 6 (-10dB), to obtain a drop of
exactly -10,0 dB.

(981214)