ADJUSTMENT PROCEDURE:


CAUTION:
Before making any adjustment let the unit heat-up at least 10 min.


Always check the DC voltages at the power supply.

1) The DC voltage in TP201 shall be +280V (265-295).

2) The DC voltage in TP203 shall be +15,0V (14,7-15,3).


3) The DC voltage in TP204 shall be -15,0V (14,7-15,3).



ADJUSTMENT OF PSU:

1) The DC voltage in TP202 shall be +240V.

Adjust with P202.


THE GRE SHALL BE MARKED 1.005-1.175


ADJUSTMENT OF BASIC GAIN:

1) Set the

“OUTPUT GAIN” on “+10”.


2) Set the Low-

Mid and High “Gain” on “+10”.


3) Apply a signal of 1 kHz, -20,0 dBU to input.


9)

Adjust the preset “Gain” P1 (P101) (on amp/psu PCB) to an output reading of 0,0 dBU.



ADJUSTMENT OF COMPRESSION:

LOW BAND:


1) Turn all the THRESHOLD-controls fully counter-clockwise.


2) Turn the LOW BAND GAIN-control fully clockwise.


3) Turn the MID BAND and HIGH BAND GAIN-control fully counter-clockwise.


4) Set the X-OVER LOW at 300 (1,2k).


5) Set the X-OVER LOW multiplier at x4.

(030318)