Connecting ethernet, Grounding – Ubiquiti Networks airFibe5 User Manual

Page 13

Advertising
background image

10

Chapter 2: Installation

airFiber

®

AF5/AF5U User Guide

Ubiquiti Networks, Inc.

4. Align the two upper Pre-Installed M10x25 Flanged Bolts

of the airFiber radio next to the slots on the Upper
Mount Bracket
. Lift the airFiber radio and seat the bolts
in the slots.

Grounding

To attach a ground wire:
1. Remove the nut from the Grounding Point.

2. Attach a ground wire (min. 8 AWG or 10 mm

2

) to the

lug and replace the nut to secure the wire.

3. Secure the other end of the ground wire to a grounded

mast, pole, tower, or grounding bar.

WARNING:

Failure to properly ground your

airFiber units will void your warranty.

Note:

The ground wire should be as short as

possible and no longer than one meter in length.

Connecting Ethernet

1. Push the button and slide the port cover down

to access cable ports. (The port cover cannot be
completely removed.)

2. Connect the Data/PoE Ethernet cable:
a. Feed an outdoor, shielded CAT6 cable up through the

rightmost cable feed slot on the bottom of the port
cover.

b. Connect the cable to the Data port.
c. Create a strain relief for the Ethernet cable by feeding a

Cable Tie through the tie slot to the side of the cable.

d. Wrap the Cable Tie around the cable and tighten.

GPS

MASTER

LINK

RESET

OVERLOAD

8X
6X
4X to 0.25X

REMOTE

LOCAL

MANAGEMENT

DATA

AUX

ACT

SPEED

ACT

SPEED