The ABC board’s Yellow Confi g LED will fl ash the current

variable speed ECM blower speed selections for low, med,

and high continuously with a short pause in between. The

speeds can also be confi rmed with the AID Tool under the

Setup/ECM Setup screen. The variable speed ECM blower

motor speeds can be fi eld adjusted with or without using

an AID Tool.

Variable Speed ECM Setup without an AID Tool

The blower speeds for Low (G only), Med (Y1), and High

(Y2/Aux) can be adjusted directly at the Aurora ABC board

which utilizes the push button (SW1) on the ABC board.

This procedure is outlined in the Variable Speed ECM

Confi guration Mode portion of the Aurora ‘Base’ Control

System section.

Variable Speed ECM Setup with an AID Tool

A much easier method utilizes the AID Tool to change

the airfl ow using the procedure below. First navigate to

the Setup screen and then select ECM Setup. This screen

displays the current variable speed ECM settings. It allows

the technician to enter the setup screens to change the

variable speed ECM settings. Change the highlighted item

using the

◄ and ► buttons and then press the ◙ button to

select the item.

Setting Blower Speed - Variable Speed ECM

Variable Speed ECM Speed Setup -

These

screens allow the technician to select the low, medium,

and high blower speed for the variable speed ECM blower

motor. Change the highlighted item using the

▲ and ▼

buttons. Press the

◙ button to select the speed.

After the high speed setting is selected the AID Tool will

automatically transfer back to the ECM Setup screen.

Variable Speed ECM Setup with an AID Tool cont.

Selecting YES will enter variable

speed ECM speed setup, while

selecting NO will return to the

previous screen.

ECM SPEED INFO

LOW SPEED: 3
MED SPEED: 5
HIGH SPEED: 7

WANT TO CHANGE?

YES

OPTION ◄►

NO

ENTER ◙

ECM SPEED INFO

1
2 <– LOW
3
4
5
6
7
8
9
10
11
12

OPTION ◄►

ENTER ◙

ECM SPEED INFO

1
2 LOW
3
4
5 <– MED
6
7
8
9
10
11
12

OPTION ◄►

ENTER ◙

ECM SPEED INFO

1
2 LOW
3
4
5 MED
6
7
8
9
10
11
12 <– HIGH

OPTION ◄►

ENTER ◙

Setting Blower Speed - Variable Speed ECM - UPC Controls

Variable speed ECM blower motors have 12 selectable speeds and are factory set for optimum performance. When

applicable, the speed settings may also be adjusted through the Building Automation System (BAS).

Setting Blower Speed - Variable Speed ECM - Aurora Controls

CAUTION: Disconnect all power before performing this operation.