Model nomenclature, Versatec ultra series installation manual – WaterFurnace Versatec Ultra User Manual

Page 4

Advertising
background image

4

VERSATEC ULTRA SERIES INSTALLATION MANUAL

Model Nomenclature

U

S

1

3

4-6

7

8

9

Model Type
U – Versatec Ultra

Operation Range
S – Single Stage

Cabinet Configuration
V – Vertical
H - Horizontal

Unit Capacity (MBTUH)
009, 012, 015, 018,
023 (Horizontal)
024, 030, 036,
041 (Vertical)
042, 048, 060, 070

Discharge Configuration
T – Top (Vertical)
E – End (Horizontal)
S – Side (Horizontal)

Return Air Configuration
L – Left
R – Right

Voltage
0 – 208-230/60/1
2 – 265-277/60/1 (009-036)
3 – 208-230/60/3 (023-070)
4 – 460/60/3 (023-070)
5 – 575/60/3 (PSC Only 041-070)

Hot Water Generation Option

2

0 – No HWG, No IntelliStart

®

2 – HWG w/o Pump, No IntelliStart
(Vertical 015-070)
3 – No HWG, IntelliStart
5 – HWG w/o Pump, IntelliStart
(Vertical 018-070)

Blower Options
0 – PSC Blower
1 – Variable Speed ECM Blower (015-070)
2 – High Static Variable Speed ECM Blower
(042-048)
3 – High Static PSC Blower (024, 030, 042, 048)
4 – 5-Speed ECM Blower (015-070)

Water Coil Option
C – Copper
N – CuproNickel

Vintage
* - Factory Use Only

Non-Standard Options
SS – Standard

Drain Pan Option
0 – Composite, No Secondary Connection
1 – Composite, Secondary Connection
2 – Stainless Steel, No Secondary Connection
3 – Stainless Steel, Secondary Connection

Cabinet Option
0 – Unpainted, 1 in MERV 4, Filter Rail
1 – Painted, 1 in MERV 4, Filter Rail
2 – Unpainted, 2 in MERV 13, Filter Rail
3 – Painted, 2 in MERV 13, Filter Rail
4 – Unpainted, 1 in MERV 4, Filter Rack
5 – Painted, 1 in MERV 4, Filter Rack
6 – Unpainted, 2 in MERV 13, Filter Rack
7 – Painted, 2 in MERV 13, Filter Rack

Phase Guard

1

N – No Phase Guard, No Disconnect
P – Phase Guard, No Disconnect
B – Phase Guard, Disconnect
D – No Phase Guard, Disconnect

All-Aluminum Air Coil Option
5 – AlumiSeal

TM

/Extended Range

6 – AlumiSeal/Standard Range
7 – No Coating/Extended Range
8 – No Coating/Standard Range

Control Option
A – Aurora

TM

Base Control (ABC)

E – Aurora UPC DDC Controller
F – Aurora UPC DDC Controller with LON

Water Control Option
N – None
R – Water Flow Regulator (015-070)
V – 2-Way Valve (015-070)
B – 2-Way Valve w/ Water Flow Regulator
(015-070)

Refrigeration Option
0 – None
G – Hot Gas Bypass (015-072)
R – Hot Gas Reheat (015-072)
B – Hot Gas Bypass w/Hot Gas Reheat (015-072)

Sound Kit Option
A – None
B – Sound Kit (Not Available on H009-012)

Rev.: 24 April 2014D

10

11

12

14

V

036

T

L

0

0

0

C

A

N

13

N

15

A

16

5

17

N

18

0

19

0

20

SS

21-22

*

23

Notes:
1 -
Phase Guard Only Available on 208-230/60/3, 460/60/3, and 575/60/3
2 - IntelliStart is not available with Phase Guard

2