Fume extraction

Fume extraction must be arranged in such a way as to provide complete
extraction of all products of combustion to an area outside the living area.

The flue system must slope in an upward direction in order to avoid a
build-up of condensation.

Fitting the fume flue in the upper ventilation grille

6.7

6.7.1

min. 10 mm
max. 20 mm

An installation that is not carried out by qualified persons causes a
reduction in the cooling capacity and will jeopardize the manufactur-
er's guarantee.

1. Connect T-piece (E) to adaptor (F) or tail pipe (K) as required and affix with

screw (G). Ensure that heat baffle (H) is lodged in the correct position.

2. Insert flue pipe with cover plate (C) through the appropriate aperture in frame (I)

and connect to T-piece (E). If necessary, shorten flue pipe (C) to the required
length.

3. Insert ventilation grille(D) into mounting frame (I) and fasten, using the locking

handle on the left of the grille.

4. Insert extractor insert (A) into ventilation grille (D).