PNOZ msi5p

Operating Manual PNOZ msi5p
21465-EN-03

3

Connection

PNOZ msi5p

Incremental encoder

Drive

PNOZ ms2p

PNOZ ms3p

PNOZ ms4p

PNOZ s30

Connector pin assignment

A

B

GND

/A

/B

15

9

8

1

X1

X2

15

9

8

1

INFORMATION
The signals Z and /Z for the speed monitor PNOZ s30 are not recorded.

CAUTION!
Communication errors may occur if the adapter cable is too long or there
are any external sources of interference. Use an adapter cable that’s less
than 5 m in length. Lay the adapter cable separately from any potential
sources of interference, such as drive cables leading to the motor, for exam-
ple.