2 handshake-controlled communication mode, Handshake­controlled communication mode – Pilz PIT m3.2p machine tools pictogram User Manual

Page 31

Advertising
background image

Function description

Operating Manual PIT m3.2p
1003176­EN­02

31

4.3.2.2

Handshake­controlled communication mode

With handshake­controlled communication mode, the download of the Key ID number is
started by the control system (Request). 
Features of this communication mode:

}

Download starts via a request to the control system, once the transponder key is con­
nected

}

Download is repeated by a renewed request to the control system

}

Variable bit rate (min. 2 PLC cycles per bit)

}

Download on 1 data line

}

Typical download time: 28 Bit * (20 ms + 4 * PLC cycle)

}

Identifier for ID end for feasibility check

}

Input/outputs required on the control system: 3 inputs and 1 output

The Key ID interface must be coded with a jumper between IDo3 and IDi1 in order to down­
load the Key ID number of a transponder key to the control system in handshake­controlled
communication mode. The terminals on the Key ID interface are used as follows:

Key ID interface

Brief description of applic­
ation

Coding via jumpers

IDo0

IDsync

IDi1

Coding: IN

IDo3

Coding: OUT

IDo1

IDresponse

IDo2

IDdata

IDo3

Coding: OUT

IDi0

IDrequest

IDi1

Coding: IN

In handshake­controlled communication mode, the operating mode selector switch can be
operated in a functional variant. In this case the Key ID number of the transponder key is
not downloaded to the control system. The control system is only used to evaluate IDo0 on
the Key ID interface. In this case IDo0 is used as a signal output, enabling the control sys­
tem to recognise whether the transponder key is valid/invalid. With this functional variant,
only 1 input is required on the control system. The unused terminals on the Key ID interface
(IDo1, IDo2 and IDi0) may remain unwired ("open").