3 monitoring of operating time, 4 switchover delay t1, Monitoring of operating time – Pilz PIT m3.2p machine tools pictogram User Manual

Page 50: Switchover delay t1

Advertising
background image

Operation

Operating Manual PIT m3.2p
1003176­EN­02

50

7.3

Monitoring of operating time

The switch to a different operating mode is only recognised once the corresponding button
has been operated for a defined period.

Button's operating time

Button

Operating mode

Output

Operating time

1

OM1

SOM1

> 50 ms and

< 5 s

2

OM2

SOM2

3

OM3

SOM3

4

OM4

SOM4

1

OM5 (Service)

SOM5

> 5 s and

< 10 s

7.4

Switchover delay t1

Once a button has been released, the assigned output on the operating mode interface
switches to a "1" signal after the switchover delay t1 has elapsed (see 

Technical details [

 54]

). This defined switchover delay guarantees that only one operating mode at a

time has a "1" signal at the assigned output.

SOM1

SOM2

SOM3

SOM4

SOM5

t1

t1

Fig.: Time behaviour when switching operating mode