Nexen RSTC1000 964523 User Manual

Page 11

Advertising
background image

FORM NO. L-21208-C-0908

8

S

ETUP

60: Tension Monitor Enable Sent as integer, read & write. Tension Output Enable has values of 0 for Off and 1 for
On. Set to 1 for actual tension to be available on Control Output B. Set to 0 for the controlling or standby outputs to
be available on Control Output B. Splice B register command and hardware input is ignored when Tension Output En-
able is set to 1.
Example:

1

Register 56: 0 (msb), 1 (lsb)

61: Tension Alarm Tolerance Sent as integer, read & write. Tension Alarm Tolerance has a range of 0–100%.
Example:

25%

Register 61: 0 (msb), 25 (lsb)

Tension Alarm Tolerance = (0 * 256) + 25 = 25%

62: Alarm Output Type Sent as integer, read & write. Alarm Output Type has values of 0 for Normally Open and 1 for
Normally Closed.
Example:

1

Register 62: 0 (msb), 1 (lsb)

63: Torque Actuator Sent as integer, read & write.
Torque Actuator has the following values:

1 – Pneumatic Brake

2 – Pneumatic Clutch

3 – Magnetic Particle Brake

4 – Magnetic Particle Clutch

5 – Electric Brake

6 – Electric Clutch

7 – Motor-Drive System

Example 2 – Pneumatic Clutch

Register 63: 0 (msb), 2 (lsb)

64: Torque Actuator Inertia Sent as integer * 100 in units of lb-ft

2

, read & write. Torque Actuator Inertia has a range

of 0.00 to 100.00

Example 21.37 lb-ft

2

Register 64: 8 (msb), 89 (lsb)

Torque Actuator Inertia = ((8 * 256) + 89) / 100 = 21.37 lb-ft2

65: Tension Zone Selection Sent as integer, read & write. Tension Zone Selection has values of 1 for Unwind and 2
for Wind.

Example 2 – Pneumatic Clutch

Register 65: 0 (msb), 2 (lsb)

66: Minimum Output % Sent as intger, read & write. Minimum Output has a range of 0–100 %.
Example

32%

Register 66: 0 (msb), 32 (lsb)

67: Maximum Output % Sent as intger, read & write. Maximum Output has a range of 0–100 %.
Example

10%

Register 67: 0 (msb), 10 (lsb)

68: Standby Output % Sent as intger, read & write. Standby Output has a range of 0–100 %.
Example

67%

Register 68: 0 (msb), 67 (lsb)

69: Web Material Selection Sent as integer, read & write. Web Material Selection has values of 1 for paper and
plastic, 2 for aluminum, and 3 for steel.

Example 2 – aluminum

Register 69: 0 (msb), 2 (lsb)

Advertising