two connectors would cancel one another, and the

hub-to-hub connection would fail.)

Thus the rule for making a hub-to-hub connection

with twisted-pair cable is as follows:

To make a hub-to-hub connection with a

straight cable, Uplink must be selected at

one end of the cable, and Uplink must not

be selected at the other end of the cable.

To make a hub-to-hub connection with a

cross-over cable, Uplink must not be

selected at either end of the cable.

To connect the Ethernet Hub to a thin coaxial

cable (lOBase2 cable, also known by its wire-

standard name, RG58A/U, and a variety of other

informal names), first twist a BNC T-connector

onto the rear-panel BNC connector of the

Ethernet Hub. Then twist the shell of the cable’s

connector onto either leg of the BNC T.

If the thin coaxial cable continues on to other

nodes, then twist the shell of the continuation

cable onto the remaining leg of the BNC T. If

there is no continuation (the Ethernet Hub is at

the end of the coaxial cable), then it is necessary to

twist a 50-ohm terminator onto the remaining

open leg of the BNC T.