Dimensions – ABUS Technologies HART? Block Temperature Transmitter User Manual

Page 5

Advertising
background image

ABUS TECHNOLOGIES INC.

5


HART

Block

ENVIRONMENT CONDITIONS

Ambient temperature:

-40 ~ 85°C (-40°F ~ 185°F)

Storage temperature:

-40 ~ 100°C (-40°F ~ 212°F)

Condensation:

Allowable

Degree of protection:

IP00

Shock and vibration resistance:

4g/2 ~ 150 Hz as per IEC 60 068-26

Electromagnetic compatibility (EMC): Interference immunity and interference emission

according to GB/T17626.2 (1998), compliance with IEC
61 000-4-3 (1995).

Installation Instruction:

Installation angle: no limit.

MATERIALS

Dimensions:

Dia. 44 mm x 22.5 mm

Materials:

Housing: PC, Plotting: epoxy

Weight: Approx.

33.5 g

Maximum measured error

INPUT

TYPE

MEASUREMENT ACCURACY

Resistance thermometer RTD

Pt100, Ni100
Pt500, Ni500

Pt1000, Ni1000

Cu50

Cu100

0.2 K or 0.08 %
0.5 K or 0.20 %
0.3 K or 0.12 %
0.2 K or 0.08 %
0.3 K or 0.12 %

Thermocouple TC

K, J, T, E

N

S, B, R

Typ.0.5K or 0.08 %
Typ.1.0K or 0.08 %
Typ.2.0K or 0.08 %

Resistance transmitter (Ω)

0 to 400 Ω

0 to 2000 Ω

0 to 10000 Ω

±0.1 Ω or 0.08 %
±1.5 Ω or 0.12 %
±7.5 Ω or 0.20 %

Voltage Transmitter (mV)

-10 to 75 mV

-100 to 100 mV
-100 to 500 mV

-100 to 2000 mV

±20 μ V or 0.08 %
±20 μ V or 0.08 %
±30 μ V or 0.08 %
±50 μ V or 0.08 %

3. DIMENSIONS


Advertising