SETTING UP CAT5E/6/7

NO POWER ON THE EXTENDERS

IMAGE IS BAD/FLICKERS

CAT5E or higher is recommended for use with the Atlona AT-PROHD48M-SR. If cables are run in the

walls make sure to stay away from light fixtures, electrical boxes, fluorescent lights, and any or other

electrical cables to reduce and prevent signal degradation. T568B termination needs to be used for this

device.

Pin T568A Pair T568B Pair Wire

T568A Color

T568B Color

Pins on plug face

(socket is reversed)

1

3

2

tip

white/green stripe

white/orange stripe

2

3

2

ring

green solid

orange solid

3

2

3

tip

white/orange stripe white/green stripe

4

1

1

ring

blue solid

blue solid

5

1

1

tip

white/blue stripe

white/blue stripe

6

2

3

ring

orange solid

green solid

7

4

4

tip

white/brown stripe

white/brown stripe

8

4

4

ring

brown solid

brown solid

If the unit is not powering-on please double check the surge protector/ outlet that the unit is connected

to. A Volt Meter can also be used to check the unit and the power supply needs to be outputting 12V

DC (110/240v universal).

1 2 3 4 5 6 7 8

Pin Position

The image flickers, goes in and out, or there is snow like affect, there are multiple reasons for this is-

sues. Check all the connections HDMI and CAT5E/CAT6 and make sure they are fully connected and

are not loose. Check to see the CAT5E/CAT6/CAT7 terminations are fully crimped. CAT5E/CAT6/CAT7

is pick¬ing interference from other cables in the wall. Shielded cables are recommended to be run in

the walls. CAT5E/CAT6/CAT7 wall plates or CAT5 terminal blocks should not be used as they can also

cause inter¬ference in the signal; it needs to be connected with cables direct. The CAT5E/CAT6/CAT7

cables should not exceed the distance they are meant to be run at. It is important to use T568B termina-

tion on the CAT5E/CAT6/CAT7 cables.