Rs-232, Command – Atlona AT PRO2HD88M User Manual

Page 11

Advertising
background image

Toll free: 1-877-536-3976
Local: 1-408-962-0515

11

atlona.com

RS-232

Connection

RS-232 is connected through a 9-pin female D connector. The pins will have functions
associated with them, some will be unassigned.

No.

Pin

Function

1

----

Not used

2

Tx

Transmit

3

Rx

Receive

4

----

Not used

5

Gnd

Ground

6

----

Not used

7

----

Not used

8

----

Not used

9

----

Not used

1

2

3

4

5

9 8 7 6

Command

The command codes are very sensitive, do not change capitalization, spacing, or lettering.

Command

Feedback

Description

PWON

PWON

Power on

PWOFF

PWOFF

Power off

All#

All#

Resets all inputs to corresponding outputs (in3 to out3)

x1$

x1$

Turns off output channel (to turn off output 3 = x3$)

x1AVx2

x1AVx2

Switch input to output (input 3 to output 5 = x3AVx5)

x1AVx2,x3,x4

x1AVx2,x3,x4

Switch input to multiple outputs (input 3 = x3AVx1,x2)

RS232zoneX[command]

ex: RS232zone1[PWON]

RS232zoneX[command]

ex: RS232zone1[PWON]

Send commands to devices connected to the receiver RS-232 ports.
Commands are the same as the ones stated in this table.
X = zone number
example: Turning the power on for the device connected in zone 1

Statusx1

x7AVx1

Shows what input is connected to selected output

Status

x1AVx1, x2AVx2,
x3AVx4, ....

Displays which inputs are currently connected to which outputs

SaveY

(ex. Save2)

SaveY

(ex. Save2)

Saves settings for future use, preset options 0 to 9

RecallY

(ex. Recall2)

RecallY

(ex. Recall2)

Recalls saved settings for the number you selected

ClearY

(ex. Clear2)

ClearY

(ex. Clear2)

Erases the save for the number you selected

Mreset

Mreset

Sets matrix back to the default settings

Each command or feedback is terminated with a carriage return.

Note: If the command fails or is incorrect the feedback should be “Command FAILED”

Advertising