RS-232

Connection

RS-232 is connected through a 9-pin female D connector. The pins will have functions
associated with them, some will be unassigned.

No.

Pin

Function

1

----

Not used

2

Tx

Transmit

3

Rx

Receive

4

----

Not used

5

Gnd

Ground

6

----

Not used

7

----

Not used

8

----

Not used

9

----

Not used

1

2

3

4

5

9 8 7 6

Command

The command codes are very sensitive, do not change capitalization, spacing, or lettering.

System Command

Feedback

Function

Type

(Model #)

Brings up the model information

Lock

Lock

Locks the front panel of the Matrix switcher

Unlock

Unlock

Unlocks the front panel of the Matrix switcher

Version

(Firmware #)

Brings up the firmware version

Each command or feedback is terminated with a carriage return.

Note: If the command fails or is incorrect the feedback should be “Command FAILED”

Command

Feedback

Description

PWON

PWON

Turns power on

PWOFF

PWOFF

Turns power off

Statusx1

x1AVx2

Shows what input is connected to selected output

Status

x1AVx1, x2AVx2,
x3AVx4, ....

Displays which inputs are currently connected to which
outputs

Save[Y]

Save2

Saves settings for future use, saves vary from 0 to 9

Recall[Y]

Recall2

Pulls up saved settings for the number you selected

Clear[Y]

Clear2

Erases the save for the number you selected

EDIDMx1AVx2

EDIDMx1AVx2

Copies the EDID from output (x1) to Input (x2)
(output 3 to input 7 = EDIDMx3AVx2)

EDIDMInit

EDIDMInit

Resets EDID to factory settings

Undo

Undo

Cancels the previous command