background image

In

st

al

la

ti

o

n

:

S

ta

ge

9

Page 13 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

EAD2 - Electric Advance & Drop V2

To adjust the travel distance out position, loosen the 2 switch bolts on the side of the
advance arm shown below in the detailed view. Slide the switch to adjust the travel.

Sliding the switch backwards towards the wall will reduce the travel distance.
Sliding the switch forwards towards the screen will increase the travel distance.

Travel Switch Adjustment

This is the only adjustable switch.
All other switches are factory set.



Travel Distance

Max Travel Position

+

-

+

-