Page 15 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

ET / ET60 - Electric Tilt Mechanism

ET Electric Tilt Mechanism - Trouble shooting guide

Having problems? - Check the following:

1. Are all the connections correct?
2. Is the mechanism being operated correctly?

If the mechanism does not operate correctly, check the items listed in the table below.
Should the problem persist, there may be a malfunction. If this is the case, disconnect the
mains power immediately and contact your installer

Symptom

Cause

Remedy

Page

Emergency stop removed

Replace emergency stop

13

Remote control or batteries

faulty

Replace batteries or remote

14

Motor or control box faulty

Apply mains power directly, via AC1

on control box

16

Incorrect pin configuration

Terminate 8-pin RJ45 to 568/b pin

configuration

12

Faulty wiring

Replace connector or cable

12

Faulty control box

Test contact closure on control box

12

Incorrect settings

Refer to instructions

13

Incorrect pin configuration

Terminate 6-pin RJ11 to

configuration supplied

13

ASC11 protocol error

Amend Protocol

13

Mechanism not working

Contact closure not working

RS232 not working